Description
• 9 outputs which can be fl exibly confi gured to operate 1 to 9-part variable ratio nutrient dosing, pH raise, pH lower, Irrigation, add water or alarm
• Output voltage same as supplied voltage 12V to 24V AC or DC, normally 24V DC supplied (Please contact Autogrow before using an AC power supply)
• Nutrient measurement units EC, CF or TDS (EC x 500/640/700)
• Measured range 0.1 to 9.9EC, 1 to 99CF, 50 to 4950 ppm (500 ppm), 64 to 6336 ppm (640 ppm) and 70 to 6930 ppm (700 ppm)
• Nutrient resolution 0.1 mS/cm, 1 CF, 50 ppm
• Nutrient measurement accuracy +/- 0.1 EC, 1 CF or 50ppm – temperature compensated
• Nutrient dosing range 0.1 EC to 5.9EC, 1 to 59CF, 50 to 2950 ppm (500 ppm), 64 to 3776 ppm (640 ppm) and 70 to 4130 ppm (700 ppm)
• pH resolution and accuracy – 0.1 pH
• pH measurement range 2 pH to 12 pH
• Temperature resolution and accuracy 1°C, 2°F
• Temperature measuring range 0-50°C, 32-125°F
• Operating temperature range 0-45°C, 32-110°F (and not in direct sunlight)
• Large graphics display using simple four key interface
• Dosing fail safe shut-off (can be disabled)
• if nutrient is below 0.1 EC, 1 CF, 50 ppm or greater than 6.0 EC, 60 CF, 3000 ppm
• if pH below 4.5 pH or above 8.0 pH
• USB connection and software supports multiple controllers
Reviews