Products

50103002 XS Cond 50 VioLab Bench conductivity meter – Cell 2301 T

Professional bench conductivity meter with innovative high definition color LCD display, with possibility of brightness adjustment.
Conductivity measurement, TDS, with temperature display.
Possibility to select the parameters you want to see on the display.
The online guide in setup and calibration allows a simple and immediate use of the device.
Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point.
Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10).
Adjustable reference temperature and selectable cell constant.
Indication with icons of the calibrated values.
Measurement stability indicator and possibility to select 3 stability levels.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnosis messages.
Measuring range:
Cond: 0.0 microS … 199.9 mS (0.01 microS – automatic)
TDS: 0.01 mg / l … 200 g / l
Temperature: 0 … + 100.0 (0.1 ° C)
Supplied as standard:
Electrode holder stand, conductivity standard, power supply and instructions for use.
Complete with cell 2301T with built-in temperature sensor, 1m fixed cable.

AED 1,650.00

Description

Accuracy (Cond)
±2 % f.s.
Accuracy (Temperature)
±0,5 °C
Power supply
100 – 240 V
Temperature coefficent (max)
0,00 … 10,00 % / °C
Temperature compensation
0,0 … 100,0 °C
Cell constant
0.1 / 1 / 10 selectable
Description

Complete with 2301T cell with built-in temperature sensor, 1 m fixed cable

Dimension 160 x 140 x 45 mm
Display
High-definition, backlit colour LCD
TDS factor
0,40 … 1,00
Stability filter
3 levels
Warranty
3 anni
IP protection
54 IP
Online help
Yes
Buffer used indication
Yes with icon
Inputs
BNC – RCA
Name
Cond 50 VioLab
Weight
0.38 kg
Points of calibration Cond
1 … 4
Cond measuring range
0,00 µS … 200 mS
TDS measuring range
0.1 mg/l … 200 g/l
Temperature measuring range
0,0 … +100,0 °C
Calibration report
Cond resolution
0,01 – 0,1 – 1 µS / 0,01 – 0,1 mS µS/cm – mS/cm
Temperature resolution
0,1 °C
Standard approved Cond
84 µS – 147 µS – 12,88 µS – 111,8 µS – 1 valore user
Working temperature
0 … +45 °C
Reference temperature
0 … +45 °C

 

Reviews

There are no reviews yet.

Be the first to review “50103002 XS Cond 50 VioLab Bench conductivity meter – Cell 2301 T”

Your email address will not be published. Required fields are marked *

Post comment