Products

MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger

Measures and records CO2 in buildings and other non-condensing environments.

IMPORTANT INFORMATION
Requires either Onset’s HOBOware software or a compatible mobile device or Windows computer and the HOBOconnect app. System requirements for the app can be found at the bottom of the HOBOconnect software page.

 

AED 2,497.00

Description

Temperature Sensor

Range
0° to 50°C(32° to 122°F)
Accuracy
±0.21°C from 0° to 50°C, see manual for plot(±0.38°F from 32° to 122°F, see manual for plot)
Resolution
0.024°C at 25°C , see manual for plot(0.04°F at 77°F , see manual for plot)
Drift
<0.1°C per year(0.18°F per year)

RH Sensor*

Range
1% to 90% (non-condensing)
Accuracy
±2% from 20% to 80% typical to a maximum of ±4.5% including hysteresis at 25°C (77°F); below 20% and above 80% ±6% typical
Resolution
0.01%
Drift
<1% per year typical

CO2 Sensor

Range
0 to 5,000 ppm
Accuracy
±50 ppm ±5% of reading at 25°C (77°F), less than 90% RH (non-condensing) and 1,013 mbar
Warm-up Time
15 seconds
Calibration
Auto or manual to 400 ppm
Non-linearity
<1% of FS
Pressure Dependence
0.13% of reading per mm Hg (corrected via user input for elevation/altitude)
Operating Pressure Range
950 to 1,050 mbar (use Altitude Compensation for outside of this range)
Compensated Pressure Range
-305 to 5,486 m(-1,000 to 18,000 ft)
Sensing Method
Non-dispersive infrared (NDIR) absorption

Response Time

Temperature
12 minutes to 90% in airflow of 1 m/s(12 minutes to 90% in airflow of 2.2 mph)
PH
1 minute to 90% in airflow of 1 m/s(1 minute to 90% in airflow of 2.2 mph)
CO2
1 minute to 90% in airflow of 1 m/s(1 minute to 90% in airflow of 2.2 mph)

Logger

Radio Power
1 mW(0 dBm)
Transmission Range
Approximately 30.5 m line-of-sight(Approximately 100 ft line-of-sight)
Wireless Data Standard
Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range
0° to 50°C ; 0 to 95% RH (non-condensing)(32° to 122°F ; 0 to 95% RH (non-condensing))
Logging Rate
1 second to 18 hours
Logging Modes
Fixed interval (normal, statistics) or burst
Memory Modes
Wrap when full or stop when full
Start Modes
Immediate, push button, date & time, or next interval
Stop Modes
When memory full, push button, date & time, or after a set logging period
Time Accuracy
±1 minute per month at 25°C(±1 minute per month at 77°F)
Power Source
4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts)
Battery Life
6 months, typical with logging and sampling intervals of 5 minutes or slower; 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life.
Memory
128 KB (84,650 measurements, maximum)
Download Type
USB 2.0 interface or via Bluetooth Smart
Full Memory Download Time
20 seconds via USB; approximately 60 seconds via Bluetooth Smart, may take longer the further the device is from the logger
LCD
LCD is visible from 0° to 50°C;(LCD is visible from 32° to 122°F);
the LCD may react slowly or go blank in temperatures outside this range
Size
7.62 x 12.95 x 4.78 cm(3.0 x 5.1 x 1.88 inches)
Weight
267.4 g(9.43 oz)
Environmental Rating IP50

Reviews

There are no reviews yet.

Be the first to review “MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger”

Your email address will not be published. Required fields are marked *